A boiler is a closed vessel in which water or other fluid is heated. The heated
or vaporized fluid exits the boiler for use in various processes or heating applications.
The quality and characteristics of water fed to a steam generator to replace that
lost by evaporation end blow down have a profound effect on the performance, life
and safety of the boiler. The chemical and physical developments within the boiler
are influenced by the composition of boiler water.
Boiler Water treatment is required for fast safe and reliable steam generation by
preventing pitting- corrosion, scaling and carryover. Boiler feed water should be
free from calcium, magnesium, silica, iron, DO, turbidity which imply poor heat
transfer, increased fuel consumption, ultimately it leads boiler destruction.
Boiler or heater treatment program should be consisting of oxygen scavengers, multifunctional
polymers, organic/inorganic phosphate conditioners, antifoaming chemicals, alkalinity
builder and various amines.
Aqua fine treatment chemicals include number of products formulated for the control
of corrosion, deposition, foaming, and carryover and condensate corrosion. Our treatment
program for steam generation system might include recommended treatment chemicals,
feeding procedures, control units and instrumentation for monitoring and control.
To assure that a steam generation treatment program performs as careful monitoring
of all critical parameters is required.
AQUAFINE 900 | Oxygen Scavenger | Boiler Water Chemical |
AQUAFINE 900C | Scale & Corrosion Inhibitor | Boiler Water Chemical |
AQUAFINE 901C | Scale & Corrosion Inhibitor | Boiler Water Chemical |
AQUAFINE 905 | PH - Booster | Boiler Water Chemical |
AQUAFINE 909 | PH - Booster | Boiler Water Chemical |
AQUAFINE 910 | Antiscalant | Boiler Water Chemical |
AQUAFINE 911 | Antiscalant | Boiler Water Chemical |
AQUAFINE 920 | Sludge Conditioner | Boiler Water Chemical |
AQUAFINE 925 | Sludge Conditioner | Boiler Water Chemical |
AQUAFINE 925 P | Sludge Conditioner | Boiler Water Chemical |
AQUAFINE 927 | Sludge Conditioner | Boiler Water Chemical |
AQUAFINE 930 | Oxygen Scavenger | Boiler Water Chemical |
AQUAFINE 930 P | Oxygen Scavenger | Boiler Water Chemical |
AQUAFINE 935 | Oxygen Scavenger cum Scale Inhibitor | Boiler Water Chemical |
AQUAFINE 940 | Scale Inhibitor | Boiler Water Chemical |
AQUAFINE 945 | Scale Inhibitor | Boiler Water Chemical |
AQUAFINE 950 | Corrosion Inhibitor | Boiler Water Chemical |
AQUAFINE 955 | Amine Based Corrosion Inhibitor | Boiler Water Chemical |
AQUAFINE 960 | Organic Corrosion Inhibitor | Boiler Water Chemical |
AQUAFINE 965 | Amine based Organic Corrosion Inhibitor | Boiler Water Chemical |
AQUAFINE 970 | Oxygen Scavenger | Boiler Water Chemical |
AQUAFINE 975 | Oxygen Scavenger | Boiler Water Chemical |
AQUAFINE 977 | Oxygen Scavenger cum corrosion inhibitor | Boiler Water Chemical |
AQUAFINE 980 | Scale Inhibitor (Silica Inhibitor) | Boiler Water Chemical |
AQUAFINE 985 | Pre-cleaning Chemical for new boiler | Boiler Water Chemical |
AQUAFINE 988 | Preservative – Scale & Corrosion Inhibitor | Boiler Water Chemical |
AQUAFINE 990 | Oxygen Scavenger for stand by boiler | Boiler Water Chemical |
AQUAFINE 995 | Oxygen Scavenger SPL | Boiler Water Chemical |
AQUAFINE 999 | Oxygen Scavenger SPL | Boiler Water Chemical |
Cooling water treatment program is integrated part of all industries. Four or more
problems occur with cooling water system operation like & metallurgical failure
and breaks corrosion scaling, fouling, microbiological growth. Ultimately it leads
poor heat transfer, quality of the process open and close recirculation system.
Program consists of cathodic, anodic and adsorption co antiscalant/dispersant, micro
biocides which facilitate clean heat transfer surface, lowers all types of corrosion
and minimize fouling thus keep cooling tower fins and louvers clean and free from
algae fungus and slime growth.
AQUAFINE 100 | Scale & Corrosion Inhibitor – Closed system | Cooling Water Chemical |
AQUAFINE 101 | Scale & Corrosion Inhibitor | Cooling Water Chemical |
AQUAFINE 102 | Scale & Corrosion Inhibitor - CT | Cooling Water Chemical |
AQUAFINE 105 | Scale & Corrosion Inhibitor for closed system | Cooling Water Chemical |
AQUAFINE 107 | Corrosion Inhibitor for closed system - SPL | Cooling Water Chemical |
AQUAFINE 108 | Scale & Corrosion Inhibitor for closed system | Cooling Water Chemical |
AQUAFINE 109 | Corrosion Inhibitor for closed system - SPL | Cooling Water Chemical |
AQUAFINE 110 | Water Softener Dispersant | Cooling Water Chemical |
AQUAFINE 111 | Water Softener Dispersant | Cooling Water Chemical |
AQUAFINE 115 | Corrosion Inhibitor - CT | Cooling Water Chemical |
AQUAFINE 120 | Dispersant – Scale Inhibitor | Cooling Water Chemical |
AQUAFINE 125 | Dispersant – Scale Inhibitor | Cooling Water Chemical |
AQUAFINE 130 | Scale Inhibitor for Silica | Cooling Water Chemical |
AQUAFINE 135 | Scale & Corrosion Inhibitor for Hard water | Cooling Water Chemical |
AQUAFINE 140 | Food Grade Non Toxic Corrosion Inhibitor | Cooling Water Chemical |
AQUAFINE 145 | Food Grade - Scale & Corrosion Inhibitor | Cooling Water Chemical |
AQUAFINE 150 | Bio-Dispersant | Cooling Water Chemical |
AQUAFINE 155 | Bio-Dispersant | Cooling Water Chemical |
AQUAFINE 160 | Dispersant (Alkaline Based) | Cooling Water Chemical |
AQUAFINE 165 | Alkaline Scale Inhibitor | Cooling Water Chemical |
AQUAFINE 170 | Silica Scale Inhibitor | Cooling Water Chemical |
AQUAFINE 175 | Silica Scale Inhibitor – SP | Cooling Water Chemical |
AQUAFINE 180 | Scale & Corrosion Inhibitor - SP | Cooling Water Chemical |
AQUAFINE 189 | Scale Inhibitor – SP | Cooling Water Chemical |
AQUAFINE 190 | Scale & Corrosion Inhibitor Herbal Based | Cooling Water Chemical |
AQUAFINE 700 | Broad Spectrum Bicide | Biocide – Cooling Water |
AQUAFINE 700P | Broad Spectrum Bicide | Biocide – Cooling Water |
AQUAFINE 702L | Micro Bicide | Biocide – Cooling Water |
AQUAFINE 702P | Broad Spectrum Biocide | Biocide – Cooling Water |
AQUAFINE 705 | Non Toxic Biocide | Biocide – Cooling Water |
AQUAFINE 707 | Non Toxic Biocide | Biocide – Cooling Water |
AQUAFINE 710 | Oxidizing Bicide | Biocide – Cooling Water |
AQUAFINE 711 | Oxidizing Bicide | Biocide – Cooling Water |
AQUAFINE 720 | SRB Reducing Bicide | Biocide – Cooling Water |
AQUAFINE 725 | SRB Reducing Biocide | Biocide – Cooling Water |
AQUAFINE 730 | Micro Biocide | Biocide – Cooling Water |
AQUAFINE 740 | Bicide For Paper Industries | Biocide – Cooling Water |
AQUAFINE 745 | Slymicide For Paper Industries | Biocide – Cooling Water |
AQUAFINE 750 | Biocide For Paper Industries | Biocide – Cooling Water |
AQUAFINE 750 S | Mill sanitation biocide – Sugar mills | Biocide – Cooling Water |
AQUAFINE 770 | Biocide for pond & swimming pool | Biocide – Cooling Water |
AQUAFINE 777 | Biocide - swimming pool | Biocide – Cooling Water |
AQUAFINE 780 | Non Oxidizing Biocide | Biocide – Cooling Water |
AQUAFINE 789 | Biocide – chlorine based | Biocide – Cooling Water |
AQUAFINE 790 | Non Toxic Biocide | Biocide – Cooling Water |
AQUAFINE 799 | Food Grade Biocide | Biocide – Cooling Water |
Fuel additive is based upon either oregano silicon or amine based compound containing
a unique combustion catalyst, which improves the combustion of fuel oil by reducing
the fuel droplet size by the surfactant action of additives. The catalyst present
in fuel additives breaks the double bond in the long chain hydrocarbon molecule
resulting in short chain hydrocarbon, having low flash point ignites easily & burns
more rapidly.
Fuel additives also helps to reduce corrosion due to formation of SO3 gases and
reduced excessive air/oxygen and stack temperature. A 1% reduction in excess oxygen
approximately equal to 1% increase in efficiency. When excess oxygen is reduced,
so is stack temperature is also reduced. As per standard 5.5 degree Celsius drop
in stack temperature provides 0.25% efficiency gain of boilers.
Cleaning Chemicals quickly removes hardness and metal oxide deposits from boilers,
heat exchangers, condensers, evaporations, cooling jackets, process vessels, piping
and other equipment. It can be used while the equipment is on-stream or shut down.
Cleaning Chemicals can also be used to chemically clean well screens. It removes
hard water scale, corrosion Products and iron deposits.
Cleaning Chemicals can be used for removes of rust and oxide / heat scale along
with black oxide coating and chromium, zinc, And cadmium plate via the "immersion
dip method" in metal processing applications.
AQUAFINE 250 | Descaling Chemical | Descaling Chemical |
AQUAFINE 260 | Alkaline Descalant | Descaling Chemical |
AQUAFINE 270 | De-Alkaliser | Descaling Chemical |
AQUAFINE 275 | De-Alkaliser | Descaling Chemical |
AQUAFINE 280 | Hard Scale Remover | Descaling Chemical |
AQUAFINE 290 | Online Descalant | Descaling Chemical |
AQUAFINE 295 | Silica Remover | Descaling Chemical |
AQUAFINE 300 | Neutralizer | Neutralizer |
AQUAFINE 310 | Neutralizer | Neutralizer |
A suitable program is required to protect & extend the life of costly RO/UF & other
type of membrane and maintain designed product water conductivity, flow and pressure
by preventing precipitation of inorganic scales of carbonates, sulphates, oxides,
silicates, fluoride, iron etc.
Our RO Additives are highly suitable for feed water containing high silica, fluoride, sulphates, aluminium & iron oxides up to +3.00 LSI.
High performance RO Additive should be a perfect blend of phosphinocarboxylate and advance polymer or a aminophosphonate compound of higher chelation and distortion value in double deionised water to prevent precipitation and reduce particulate fouling within membrane separation.
AQUAFINE 500 | Acid Corrosion Inhibitor | Speciality Chemical |
AQUAFINE 520 | Acid Corrosion Inhibitor | Speciality Chemical |
AQUAFINE 540 | Acid Corrosion Inhibitor | Speciality Chemical |
AQUAFINE 550 | Corrosion Inhibitor | Speciality Chemical |
AQUAFINE 560 | Corrosion Inhibitor | Speciality Chemical |
AQUAFINE 1000 | Fuel Additive | Speciality Chemical |
AQUAFINE 1001 | Fuel Additive | Speciality Chemical |
AQUAFINE 1005 | Fuel Additive | Speciality Chemical |
AQUAFINE 1008 | Fuel Additive | Speciality Chemical |
AQUAFINE 1020 | Fuel Additive | Speciality Chemical |
AQUAFINE 1080 | Fuel Additive | Speciality Chemical |
AQUAFINE 6300 | Defoamer (Antifoamer) | Speciality Chemical |
AQUAFINE 6500 | Defoamer (Antifoamer) | Speciality Chemical |
AQUAFINE 6600 | Defoamer silicon based | Speciality Chemical |
AQUAFINE 6660 | Defoamer silicon free | Speciality Chemical |
AQUAFINE 4000 | R.O Antiscalant | R.O Water Chemical |
AQUAFINE 4050 | R.O Antiscalant | R.O Water Chemical |
AQUAFINE 4100 | R.O Antiscalant | R.O Water Chemical |
AQUAFINE 4200 | Antifouling | R.O Water Chemical |
AQUAFINE 4250 | Antifouling cum Antiscalant – Food Grade | R.O Water Chemical |
AQUAFINE 4300 | Antifouling cum Antiscalant | R.O Water Chemical |
AQUAFINE 4500 | R.O. Membrane antiscalant | R.O Water Chemical |
AQUAFINE 4550 | R.O. Membrane antiscalant | R.O Water Chemical |
AQUAFINE 4555 | R.O. Membrane Antiscalant - SPL | R.O Water Chemical |
AQUAFINE 4600 | R.O. Dechlorinator | R.O Water Chemical |
AQUAFINE 4650 | Anti oxidant for R.O Pretreatment | R.O Water Chemical |
AQUAFINE 4660 | Anti oxidant for R.O Pretreatment | R.O Water Chemical |
AQUAFINE 4700 | Cleaning for R.O. Membrane | R.O Water Chemical |
AQUAFINE 4710 | R.O Membrane cleaning chemical | R.O Water Chemical |
AQUAFINE 4730 | R.O Membrane cleaning chemical | R.O Water Chemical |
AQUAFINE 4750 | Cleaning for R.O. Membrane | R.O Water Chemical |
AQUAFINE 4770 | R.O Membrane cleaning chemical | R.O Water Chemical |
AQUAFINE 4800 | R.O Antiscalant | R.O Water Chemical |
AQUAFINE 4860 | R.O Antiscalant | R.O Water Chemical |
AQUAFINE 4900 | R.O Membrane preservative | R.O Water Chemical |
AQUAFINE 4950 | R.O Membrane preservative | R.O Water Chemical |
AQUAFINE 9000 | Poly Electrolyte - Cationic | Speciality Chemical |
AQUAFINE 9000 L | Poly Electrolyte - Cationic | Speciality Chemical |
AQUAFINE 9009 | Poly Electrolyte - Cationic | Speciality Chemical |
AQUAFINE 9090 | Poly Electrolyte - Cationic | Speciality Chemical |
AQUAFINE 9090 L | Poly Electrolyte - Cationic | Speciality Chemical |
AQUAFINE 9100 | Poly Electrolyte – Non-ionic | Speciality Chemical |
AQUAFINE 9100 L | Poly Electrolyte - Non-ionic | Speciality Chemicall |
AQUAFINE 9150 | Poly Electrolyte - Non-ionic | Speciality Chemical |
AQUAFINE 9200 | Poly Electrolyte - Non-ionic | Speciality Chemical |
AQUAFINE 9200 L | Poly Electrolyte - Non-ionic | Speciality Chemical |
AQUAFINE 9300 | Poly Electrolyte - Anionic | Speciality Chemical |
AQUAFINE 9300SP | oly Electrolyte - Anionic | Speciality Chemical |
AQUAFINE 9500 | Poly Electrolyte - Anionic | Speciality Chemical |
AQUAFINE 9500 L | Poly Electrolyte - Anionic | Speciality Chemical |
AQUAFINE 9700 | Flocculent - Poly Electrolyte - Anionic | Speciality Chemical |
AQUAFINE 9700 L | Flocculent - Poly Electrolyte - Anionic | Speciality Chemical |
AQUAFINE 9750 | Flocculent - Poly Electrolyte - Anionic | Speciality Chemical |
AQUAFINE 9900 | Decolourant | Speciality Chemical |
AQUAFINE 9900SP | Decolourant for effluent | Speciality Chemical |
AQUAFINE 9900SP | Decolourant for effluent | Speciality Chemical |
AQUAFINE 9910 | Coagulant | Speciality Chemical |
AQUAFINE 9990 | De-emulsifier | Speciality Chemical |